Power optimiser P404-4RM4MRM SolarEdge
Manufacturer: SolarEdge
INDEX: P404-4RM4MRM
The SolarEdge P404 power optimiser has an excellent efficiency of 99.5% and has been specially designed for use with SolarEdge inverters. This product has a unique solution that prevents the problem of module mismatch or partial shading.
Separate monitoring for each module greatly facilitates system management. The SolarEdge P404 has a function to reduce the voltage of each module—during installation or in case of fire.
Distinguishing features of the product:
Up to 25% more energy
Excellent efficiency (99.5%)
A unique solution that prevents the problem of module mismatch or partial shading
Maximum use of space thanks to a flexible system design
Quick mounting with one screw
Separate monitoring for each module greatly facilitates system management
Voltage reduction of each module—during installation or in case of fire
Cable length:
- input cables 0.16 m
- output cables 1.2 m
Maximum short-circuit current per MPPT [A]: | 11 |
---|---|
Number of optimisers per chain: | - |
Power [W]: | 405 |
Max. voltage [V]: | 80 |
Min. MPPT voltage [V]: | 12.5 |
Max. MPPT voltage [V]: | 80 |
Application: | Optymalizacja |
---|---|
Dimensions WxHxD [mm]: | 129 x 89 x 42.5 |
Euro efficiency [%]: | 98.8 |
---|---|
Max. efficiency [%]: | 99.5 |
Chain length - HD-WAVE and single phase inverter / number of optimisers and PV modules: | 6 - 25 |
---|---|
Chain length - three-phase inverter / number of optimisers and PV modules: | 14 - 50 |
Chain length - three-phase inverter for 277/480 V grid / number of PV modules: | - |
Chain length - three-phase inverter for 277/480 V grid / number of optimisers: | - |
Chain length - three-phase inverter for 277/480 V grid / number of optimisers and PV modules: | - |
Chain length - three-phase inverter from 15 kW / number of PV modules: | - |
Chain length - three-phase inverter from 15 kW / number of optimisers: | - |
Chain length of PV modules - three-phase inverter from 16 kW [pcs].: | - |
Chain length of PV modules - three-phase inverter from 25 kW [pcs].: | - |
Chain length of power optimisers - three-phase inverter from 16 kW and above [pcs].: | - |
Chain length of power optimisers - three-phase inverter from 25 kW [pcs.]: | - |
MaximumPowerPerStringInverterSinglePhaseW: | 5250 |
MaximumPowerPerStringInverterThreePhaseW: | 11250 |
MaximumPowerRegardlessOfTheNumberOfStringsPer1StringForInverterGroupA: | 5250 |
MaximumPowerRegardlessOfTheNumberOfStringsPer1StringForInverterGroupB: | 11250 |
MaximumPowerRegardlessOfTheNumberOfStringsPer1StringForInverterGroupC: | 12750 |
Maximum Power per String - inverter HD-WAVE [W]: | 5700 |
Maximum Power per String - inverter three phase [W]: | 11250 |
Maximum chain power - single phase inverter [W]: | 5250 |
Minimum String Length - inverter three phase SE 3 kW / number of optimizers and PV modules: | 13 |
TheMax.LengthOfThePVModuleChainForInverterGroupA: | 25 |
TheMax.LengthOfThePVModuleChainForInverterGroupB: | 50 |
TheMax.LengthOfThePVModuleChainForInverterGroupC: | 50 |
TheMaxLengthOfTheChainOfPowerOptimizersForInverterGroupA: | 25 |
TheMaxLengthOfTheChainOfPowerOptimizersForInverterGroupB: | 50 |
TheMaxLengthOfTheChainOfPowerOptimizersForInverterGroupC: | 50 |
TheMinLengthOfTheChainOfPowerOptimizersForInverterGroupA: | 6 |
TheMinLengthOfTheChainOfPowerOptimizersForInverterGroupB: | 14 |
TheMinLengthOfTheChainOfPowerOptimizersForInverterGroupC: | 14 |
TheMinLengthOfThePVModuleChainForInverterGroupA: | 6 |
TheMinLengthOfThePVModuleChainForInverterGroupB: | 14 |
TheMinLengthOfThePVModuleChainForInverterGroupC: | 14 |